160315_1 D702 Groundwork installation cartridge - DOCECITY.COMhttps://b451c108ef7ce3b912eb-75c7695d67180639ae25fac6b37d4ead.ssl.cf3.rackcdn.c...
0 downloads
172 Views
98KB Size
NOTES: 1. Dimensions in millimetres. (1000mm = 1m) 2. General tolerance of dimensions in the drawing: 5mm. 3. Admissible floor load: >30 kN/m2. 4. Recommended distance between RBT and display: 10m. 5. Use PVC conduits of 80mm diameter between pit and display. 6. The centerline of this excavation is offset from the test bay by 200mm to the left. 7. This drawing gives the min. excavation size for a RBT installation cartridge. 8. The hole will need to be back-filled with a "wet mix" concrete to fully support the installation cartridge.
9. When the cartridge is installed, the concrete must slope towards the drain with a min. gradient of 2%. 10. The cable entry and drainage holes are suggestions. 11. Either conduit route, straight through or under, can be used. 12. Equipment dimensions - each bed: 1440 x 660 x 300mm. 13. A separate dedicated 3-phase mains supply 400V / 50Hz / 32A with Ground + Neutral is required. 14. D702 Motors: 2 x 4kW. 15. A 4-pole safety switch should be mounted on the wall at 150mm from the control panel.
710
A
FLOOR LEVEL
355 150 430
1610
A
SECTION A-A SCALE 1 : 25
80 Test bay centerline (Recess is offset left of the test bay centerline by 200mm)
Conduit to control panel Ø 80 80
Water drain with one way valve
Slope 2% 710
Slope 2%
TOP BUILD
1610 3220
This drawing is intended as a general suggestion of a floor layout. The final construction must be carried out by your local installer who will be responsible for complying with legal and safety requirements. Drawn
DRAWN IN ACCORDANCE WITH B.S.308 DIMENSIONS IN MILLIMETRES DO NOT SCALE Tolerances Unless Otherwise Stated Angular Issue
Date
Amendment
UNLESS OTHERWISE STATED REMOVE ALL SHARP CORNERS
DOC:BOS0382
Date
D-Rodríguez 15/03/2016
Approved Original Scale
C
This print is the property of Boston Garage Equipment and is a confidential document. It must not be traced copied or exhibited to a third party without permission in writing.
B-Calcutt
FIRST ANGLE PROJECTION
Title
D702 Groundwork schematic With Installation cartridge
Drg. No.
Issue
160315_1
A