BUILDING DROPS A Perfect Solution in Every Drop  Certificate of Authorization: 29578 

 

Product Evaluation Report of

JELD-WEN, inc. Custom Collection Aluminum Clad Wood Outswing Patio Doors

for Florida Product Approval

FL# FL Report No. 1982 Florida Building Code 2010 Per Rule 9N-3 Method: Category: Sub – Category: Product: Material: Product Dimensions:

1 – D (Engineering Evaluation) Exterior Doors Swinging Exterior Door Assemblies Custom Collection Aluminum Clad Wood Outswing Patio Doors Wood (Pine) w/ Aluminum 6063-T5 cladding 153-3/16” X 129-1/8” (Maximum)

Prepared For: JELD-WEN, inc. 3737 Lakeport Blvd. Klamath Falls, OR. 97601 Prepared by: Hermes F. Norero, P.E. Florida Professional Engineer # 73778 Date: 04/11/2012 Contents: Evaluation Report Pages 1 – 4 Installation Details Pages 5 – 6

   

Digitally signed by Hermes F Norero, P.E. Reason: I am approving this document Hermes F. Norero, P.E.  Date: 2012.04.12   18:06:49 -04'00' Florida No. 73778 

BUILDING DROPS

FL#: Date: 04/11/2012 Report No: 1982

A Perfect Solution in Every Drop  Certificate of Authorization: 29578 

    Manufacturer:        Product Category:      Product Sub‐Category:      Compliance Method:      Product Name:    

JELD‐WEN, inc.  Exterior Doors  Swinging Exterior Door Assemblies  State Product Approval Rule   9N‐3.005 (1)(d) 

Custom Collection Aluminum Clad Wood Outswing Patio Doors  153‐3/16” X 129‐1/8” (Maximum)    This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for JELD‐WEN inc.  based on Rule Chapter No. 9N‐3.005, Method 1d of the State of Florida Product Approval,  Department of Community Affairs ‐ Florida Building Commission. 

Scope: 

  Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company  manufacturing or distributing the product or in any other entity involved in the approval process of  the product named herein.    This product has been evaluated for use in locations adhering to the 2010 Florida Building Code.    See Installation Instructions JW018, signed and sealed by Hermes F. Norero, P.E. (FL # 73778) for  specific use parameters.      Limits of Use:    1.    2.  3. 

5.  6. 

This product has been evaluated and is in compliance with the 2010 Florida Building Code,  excluding the “High Velocity Hurricane Zone” (HVHZ).  Product anchors shall be as listed and spaced as shown on details.  Anchor embedment into  substrate material shall be beyond wall dressing or stucco.  When used in areas requiring wind borne debris protection this product complies with  Section 1609.1.2 of the 2010 Florida Building Code and does not require an impact resistant  covering.    Site conditions that deviate from the details of drawing JW018 require further engineering  analysis by a licensed engineer or registered architect.  See Installation Instructions JW018 for size and design pressure limitations. 

                   

 

Hermes F. Norero, P.E.  Florida No. 73778  Page 2 of 6   

BUILDING DROPS

FL#: Date: 04/11/2012 Report No: 1982

A Perfect Solution in Every Drop  Certificate of Authorization: 29578 

  Quality Assurance: 

The manufacturer has demonstrated compliance of door products in Accordance  with the Florida Building Code and Rule 9N‐3.005 (3) for manufacturing under a  quality assurance program audited by an approved quality assurance entity through  Window and Door Manufacturers Association. (FBC Organization # QUA2515) 

    Performance Standards: 

The product described herein has been tested per:    

Referenced Data:         

     

 

 

AAMA/WDMA/CSA 101/I.S.2/A440‐08  ASTM E 1886‐05  ASTM E 1996‐05 

   

1. 

Product Testing performed by National Certified Testing Laboratory, Inc.  (FBC Organization # TST1589) Report #: NCTL‐210‐3729‐1A,   Report Date: 03/28/2011 

 

2.    

Quality Assurance  Window and Door Manufacturers Association  (FBC Organization #: QUA2515)  

                                             

 

 

Hermes F. Norero, P.E.  Florida No. 73778  Page 3 of 6   

BUILDING DROPS

FL#: Date: 04/11/2012 Report No: 1982

A Perfect Solution in Every Drop  Certificate of Authorization: 29578 

  Installation:   

1.   Approved anchor types and substrates are as follows:  Through Frame Installation:  A. For two by (2X) wood buck substrate, use #12 Wood Screw type installation anchors of  sufficient length to achieve a minimum embedment of 1.50” into the wood substrate.    B. For concrete or masonry substrate where one by (1X), non‐structural, wood bucking is  employed, use 1/4” diameter ITW Tapcon type concrete screw anchors of sufficient  length to achieve minimum embedment of 1.25” into concrete or masonry. 

  C. For concrete or masonry substrate where wood bucking is NOT employed, use 1/4”  diameter ITW Tapcon type concrete screw anchors of sufficient length to achieve  minimum embedment of 1.25” into concrete or masonry.      Refer to Installation Instructions (JW018) for anchor spacing and more details of the installation  requirements.    Design Pressure: 

  Configuration  O‐O‐O/OXXX  OXXX  XX  X 

           

 

 

Design Pressure  +50.0/‐50.0 PSF  +60.0/‐80.0 PSF  +60.0/‐80.0 PSF  +60.0/‐80.0 PSF 

 

                 

   

 

Hermes F. Norero, P.E.  Florida No. 73778  Page 4 of 6   

BUILDING DROPS

FL#: Date: 04/11/2012 Report No: 1982

A Perfect Solution in Every Drop  Certificate of Authorization: 29578 

 

Installation Method JELD-WEN, inc. Custom Collection Aluminum Clad Wood Outswing Patio Doors

 

 

Hermes F. Norero, P.E.  Florida No. 73778  Page 5 of 6   

BUILDING DROPS

FL#: Date: 04/11/2012 Report No: 1982

A Perfect Solution in Every Drop  Certificate of Authorization: 29578 

 

 

 

Hermes F. Norero, P.E.  Florida No. 73778  Page 6 of 6