building drops - Florida Building Commission


[PDF]building drops - Florida Building Commission8032c1fb3d623963968f-392426bfe23e9ffecbdfd263ee200e67.r75.cf1.rackcdn.com/...

34 downloads 265 Views 412KB Size

127 W. Fairbanks Ave.  Suite 438  Winter Park, FL 32789  407.644.6957 PH  407.644.2366 FX  [email protected] 

BUILDING DROPS A Perfect Solution in Every Drop  Certificate of Authorization: 29578 

 

Product Evaluation Report of

Ply Gem Windows Builder Series 4712 / 4812 Single Hung Window

for Florida Product Approval

FL# Report No. 1869 Florida Building Code 2007 & 2010 Per Rule 9N-3 Method: 1 – D (Engineering Evaluation) Category: Windows Sub – Category: Single Hung Product: Material: Product Dimensions:

Builder Series 4712 / 4812 Single Hung Window Aluminum 6063-T5 53” x 72” 48” x 84”

Prepared For: Ply Gem Windows 433 N. Main St. P.O. Box 559 Rocky Mount, VA 24151 Prepared by: Hermes F. Norero, P.E. Florida Professional Engineer # 73778 Date: 02/24/12 Contents: Evaluation Report Pages 1 – 4 Installation Details Page 5

     

Digitally signed by Hermes F. Norero, P.E. Reason: I am approving this document Date: 2012.03.12 17:35:21 -04'00'

 

 

Hermes F. Norero, P.E.  Florida No. 73778 

BUILDING DROPS

FL#: Date: 02/24/2012 Report No: 1869

A Perfect Solution in Every Drop  Certificate of Authorization: 29578 

  Manufacturer:        Product Category:      Product Sub‐Category:      Compliance Method:      Product Name:    

 

 

 

Ply Gem Windows Windows  Single Hung  State Product Approval Rule   9N‐3.005 (1)(d)  Builder Series 4712 / 4812 Single Hung Window  (Impact)  53” x 72”  48” x 84” 

 

 

 

 

  This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for Ply Gem  Windows based on Rule Chapter No. 9N‐3.005, Method 1d of the State of Florida Product Approval,  Department of Community Affairs ‐ Florida Building Commission. 

Scope: 

  Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company  manufacturing or distributing the product or in any other entity involved in the approval process of  the product named herein.    This product has been evaluated for use in locations adhering to the 2007 & 2010 Florida Building  Code.    See Installation Instructions PGW036, signed and sealed by Hermes F. Norero, P.E. (FL # 73778) for  specific use parameters.    Limits of Use:    1.    2.  3. 

4.     

 

5. 

This product has been evaluated and is in compliance with the 2007 & 2010 Florida Building  Code, excluding the “High Velocity Hurricane Zone” (HVHZ).  Product anchors shall be as listed and spaced as shown on details.  Anchor embedment into  substrate material shall be beyond wall dressing or stucco.  When used in areas requiring wind borne debris protection this product complies with  Section 1609.1.2 of the 2007 & 2010 Florida Building Code and does not require an impact  resistant covering.    Site conditions that deviate from the details of PGW036 require further engineering analysis  by a licensed engineer or registered architect.  See Installation Instructions PGW036 for size and design pressure limitations.       

     

 

Hermes F. Norero, P.E.  Florida No. 73778  Page 2 of 5   

BUILDING DROPS

FL#: Date: 02/24/2012 Report No: 1869

A Perfect Solution in Every Drop  Certificate of Authorization: 29578 

  Quality Assurance: 

The manufacturer has demonstrated compliance of window products in Accordance with the  Florida Building Code and Rule 9N‐3.005 (3) for manufacturing under a quality assurance  program audited by an approved quality assurance entity through National Accreditation  and Management Institute (FBC Organization #: QUA1789)  

  Performance Standards: 

The product described herein has been tested per:    

  Referenced Data: 

                 

 

1. 

 

 

 

2.    

   

   

   

   

 

 

 

 

AAMA/WDMA/CSA 101/I.S.2/A440‐05  ASTM E 1886‐02  ASTM E 1996‐02  Product Testing performed by National Certified Testing Laboratories  (FBC Organization # TST4744) Report #: NCTL‐110‐13262‐2  Report Date: 08/14/10     Report #: NCTL‐110‐13259‐1  Report Date: 08/14/10     Report #: NCTL‐110‐13259‐2  Report Date: 08/14/10     Report #: NCTL‐110‐13262‐1  Report Date: 08/14/10    Report #: NCTL‐110‐13264‐1  Report Date: 08/20/10    Report #: NCTL‐110‐13420‐1  Report Date: 10/22/10  Report #: NCTL‐110‐13482‐1  Report Date: 11/18/10    Quality Assurance  National Accreditation and Management Institute  (FBC Organization #: QUA1789)  

 

                     

 

Hermes F. Norero, P.E.  Florida No. 73778  Page 3 of 5   

BUILDING DROPS

FL#: Date: 02/24/2012 Report No: 1869

A Perfect Solution in Every Drop  Certificate of Authorization: 29578 

  Installation:  1.   Approved anchor types and substrates are as follows:      Flange Installation:    A. For concrete or masonry substrate where one by (1X), non‐structural, wood bucking is  employed, use 3/16” diameter ITW Tapcon type concrete screw anchors of sufficient  length to achieve minimum embedment of 1.25” into concrete or masonry.    B. For concrete or masonry substrate where wood bucking is NOT employed, use 3/16”  diameter ITW Tapcon type concrete screw anchors of sufficient length to achieve  minimum embedment of 1.25” into concrete or masonry.    C. For steel stud substrate, use #10 self‐tapping type steel anchors of sufficient length to  achieve a minimum 3 threads penetration beyond steel structure.    Fin Installation:    A. For steel stud substrate, use #8 self‐tapping type steel anchors of sufficient length to  achieve a minimum 3 threads penetration beyond steel structure.      Refer to manufacturer Installation Instructions PGW036 for anchor spacing and more details of the  installation requirements.    Design Pressure:   PRODUCT

OVERALL SIZE WIDTH

HEIGHT

DP RATING

MISSILE IMPACT RATING LARGE AND SMALL

4712F IR

53"

72"

+ 50 /- 57 PSF

MISSILE RATED LARGE AND SMALL

4712FL IR

53"

72"

+ 50 /- 57 PSF

MISSILE RATED LARGE AND SMALL

4812F IR

53"

72"

+ 50 /- 57 PSF

MISSILE RATED LARGE AND SMALL

4712F IR

48"

84"

+ 50 /- 57 PSF

MISSILE RATED LARGE AND SMALL

4712FL IR

48"

84"

+ 50 /- 57 PSF

MISSILE RATED LARGE AND SMALL

4812F IR

48"

84"

+ 50 /- 57 PSF

 

 

 

MISSILE RATED

 

Hermes F. Norero, P.E.  Florida No. 73778  Page 4 of 5   

BUILDING DROPS

FL#: Date: 02/24/2012 Report No: 1869

A Perfect Solution in Every Drop  Certificate of Authorization: 29578 

 

Installation Method Ply Gem Windows Builder Series 4712 / 4812 Single Hung Window (O/X)     SEE ANCHOR SCHEDULE

SEE ANCHOR SCHEDULE

SEE ANCHOR SCHEDULE

"O"

"X" SEE ANCHOR SCHEDULE

ANCHOR LAYOUT  

    EDGE

EMBEDMENT

JAMB O.C.

CORNER

DISTANCE

DISTANCE

(IN.)

(IN.)

(IN.)

12

9

4

20

-

18

4

20

-

18

4

HEAD

INSTALLATION

QTY PER

TYPE

LOCATION

(IN.)

(IN.)

#8 SELF-TAPPING

FIN

1

STEEL STUD

3 THREADS

N/A

12

3/16" ITW TAPCON

FLANGE

1

CONCRETE/MASONRY

1.25

2.5

#10 SELF-TAPPING

FLANGE

1

STEEL STUD

3 THREADS

N/A

ANCHOR TYPE

SUBSTRATE

DISTANCE

(IN.)

SILL

O.C. DISTANCE O.C. DISTANCE

 

 

 

Hermes F. Norero, P.E.  Florida No. 73778  Page 5 of 5