General Notes C
Core C
Signage Types Core C
FLOOR
FLATS
Ground Floor
Ground Floor
5th 4th 3rd 2nd Grd
21-25
Flats 01-05
Elevator & Stairs 02
16-20
C8 C9
11-15
1st Floor
06-10 01-05
C1
C10
Ground Floor Elevator & Stairs 01
D1
2nd Floor
D2
2nd Floor Flats 06-10
STAIRS C2
C12
Flats 11-15
C3
EXIT
EXIT
09-12
EXIT
05-08 01-04
D4
2nd Floor
2nd Floor
Flats 01-04
01 02-04
D5
C15
16-17 18-20 C17 D11
C18
ELEVATOR & STAIRS
D6
5th Floor 21-22 23-25 C19
This drawing is to be read in conjunction with all other relevant documentation including that produced by other consultants, subcontractors and suppliers. Refer to Structural Engineer's drawings and specifications for all information on structural frame/ elements. Refer to Mechanical Engineer's drawings and specifications for all information on mechanical and electrical items.
Key
3rd Floor
3rd Floor
Flats 05-08
05 06-08
All Signage drawings to be read in conjuction with each other: 1310(AS)12/04 - 1310(AS)12/13
D8
4th Floor
4th Floor
Flats 09-12
09 10-12
D9
4th Floor Flats 21-25
All products are to be suitable for their purpose. The Contractor is to install all products where noted in accordance with manufacturers' recommendations/specifications and inform the Architect of any discrepancies or changes in the specification before proceeding with the work.
1st Floor
11-12 13-15
5th Floor
All drawings are indicative only. The sub-contractor is to submit shop drawings to the contract administrator of all the relevant components and elements for comment prior to fabrication.
D3
D7
C16
C6
13-14
3rd Floor Flats 16-20
ELEVATOR & STAIRS
5th 4th 3rd 2nd
All elements of work and materials are to comply with Building Regulations and British Standards, good industry practice and the recommendations of material and component manufacturers.
Ground Floor
C13
4th Floor
C5
FLATS
06-07 08-10
C14
C4
FLOOR
ELEVATOR & STAIRS
C11
3rd Floor
EXIT
Core D
Signage Types Core D
Copyright Stephen Davy Peter Smith Architects 2014
All dimensions are given in millimetres, and internal dimensions are taken to face of blockwork. Do not scale from the drawing. All dimensions and conditions to be checked and confirmed on site by the Contractor. The Contractor should inform the Architect of any discrepancies before proceeding with the work.
D10
5th Floor
5th Floor
Flats 13-14
13-14 D12 Rev
Comment
By
Date
CONSTRUCTION
Stephen Davy Peter Smith Architects
C7 Fanshaw House, Fanshaw Street, London N1 6HX Tel: 020 7739 2020 Fax: 020 7739 2021 E-mail:
[email protected] Website: www.davysmitharchitects.co.uk
Client
TYPICAL SIGNAGE DETAILS Brushed stainless steel plate, edges rounded, 2 mm thick, sizes as shown, Text, number engraved 0.5 mm and blackened, Font: Arial, Text and arrow centred
Durkan Ltd Durkan House 214-224 High Street Waltham Cross Hertfordshire EN8 7DU Project Title
Union Road Union Road / Clapham Road Clapham SW4 Drawing Title
Signage Types - 02 Note: Drawings are indicative only. Sub-contractor to submit shop drawings prior to fabrication. Signage to comply with all relevant British Standards.
Job No.
Drawn By
Date
Checked by
1310
Oct 2014 Drawing No.
AM
Scale
1:10 @ A3
GD
1310(AS)12/06
Revision -