77.5 sqm 2B/4P
General Notes
1310(AS)04-31
Privacy screen detail
07 1310(AS)03-11
07 1310(AS)03-11
C
1B/2P
All elements of work and materials are to comply with Building Regulations and British Standards, good industry practice and the recommendations of material and component manufacturers.
6092
725
240
3035
shop drawings to the contract administrator of all the relevant components and elements for comment prior to fabrication.
W6
1437
W2
1587
RWP
07 1310(AS)02-20 All drawings are indicative only. The sub-contractor is to submit
W05 F-11
W02 F-16
Terrace
Ca
65
Ca
1050
1650
W01 F-16
overflow
1500
W03 F-15
Outlet
RWP
65
Cb W02 F-15
overflow
C10
06 1310(AS)04-30 45.5 sqm
Refer to Structural Engineer's drawings and specifications for all information on structural frame/ elements.
05 1310(AS)04-30
1B/2P
TYPICAL BALCONY TYPE C-B1: 2ND - 4TH FLOOR
Refer to Mechanical Engineer's drawings and specifications for all information on mechanical and electrical items.
C3
06 1310(AS)04-30
C2
All products are to be suitable for their purpose. The Contractor is to install all products where noted in accordance with manufacturers' recommendations/specifications and inform the Architect of any discrepancies or changes in the specification before proceeding with the work. This drawing is to be read in conjunction with all other relevant documentation including that produced by other consultants, subcontractors and suppliers.
slab edge slab edge
C9
Copyright Stephen Davy Peter Smith Architects 2013
All dimensions are given in millimetres, and internal dimensions are taken to face of blockwork. Do not scale from the drawing. All dimensions and conditions to be checked and confirmed on site by the Contractor. The Contractor should inform the Architect of any discrepancies before proceeding with the work.
W2
-
TYPICAL BALCONY TYPE C-B4: 2ND - 3RD FLOOR
1310(AS)03-11 08 Key
FG
345
08 1310(AS)03-11
M&E SW1
SVP C03
77
Cc
Ca Outlet
W01 F-14
W05 F-59
W2
Terrace 02 1310(AS)04-30
Terrace
Rev
Comment
PW LN CF TSo
18.03.16 27.06.14 22.11.13 12.09.13
WB 23.08.13
By
Date
overflow
3760
overflow
TYPICAL BALCONY TYPE C-B2: 2ND - 5TH FLOOR
Cb
1310(AS)04-31
1237.5
07 1310(AS)03-11
W2
1500
C3
Client
4 Elstree Gate Elstree Way Borehamwood Hertfordshire WD6 1JD Project Title
W2
W02 F-13
Drawing Title
Balcony / Terrace Setting Out Plans - BLOCK C
65
overflow
3188
slab edge
Job No.
C4 05 1310(AS)04-30
06 1310(AS)04-30
Fanshaw House, Fanshaw Street, London N1 6HX Tel: 020 7739 2020 Fax: 020 7739 2021 E-mail:
[email protected] Website: www.davysmitharchitects.co.uk
1650
W01 F-13
2904
08 1310(AS)03-11
BALCONY TYPE C-T2: 5TH FLOOR
215
65
W02 F-12 1050
Outlet
RWP
Ca
W6
slab edge
C2
Privacy screen detail
310(AS)02-20
Stephen Davy Peter Smith Architects
W6
-
310(AS)03-11 08
D Issued, As Built C Dims added to privacy screens, ref updated B Outlet references added A Overflows, privacy screen and handrails added, RC setting out revised - Issued for comment
3610
slab edge
C6
3112
2460
3262
1715
W6
115
AS BUILT
W2
Water butt
W03 F-13
RWP
W04 F-59
1310 06 1310(AS)04-30
TYPICAL BALCONY TYPE C-B3: 2ND - 5TH FLOOR
Drawn By
Scale
TSo
1:50 @ A3
Date
Checked by
AUG 2013
GD
Drawing No.
1310(AS)04-45
Revision D