General Notes C
BBA approved DPC cavity tray sealed to DPC to manufacturer's requirements Vandex BB75E waterproofing slurry applied to retaining wall within lift shaft and pit area, Vandex construction joint tape to joints to manufacturer details 600mm above FFL
EXTERNAL
COMMUNAL AREA GROUND FLOOR
Screed with floor finish to communal area
All dimensions are given in millimetres, and internal dimensions are taken to face of blockwork. Do not scale from the drawing. All dimensions and conditions to be checked and confirmed on site by the Contractor. The Contractor should inform the Architect of any discrepancies before proceeding with the work. All elements of work and materials are to comply with Building Regulations and British Standards, good industry practice and the recommendations of material and component manufacturers.
Proprietary perpend weep holes at max. 1000mm c/c. colour to match mortar
FFL Screed SSL Wall insulation installed to slab level
GL
COMMUNAL AREA GROUND FLOOR
Copyright Stephen Davy Peter Smith Architects 2013
B1 / LIVE WORK GROUND FLOOR
All drawings are indicative only. The sub-contractor is to submit shop drawings to the contract administrator of all the relevant components and elements for comment prior to fabrication. All products are to be suitable for their purpose. The Contractor is to install all products where noted in accordance with manufacturers' recommendations/specifications and inform the Architect of any discrepancies or changes in the specification before proceeding with the work. This drawing is to be read in conjunction with all other relevant documentation including that produced by other consultants, subcontractors and suppliers.
BBA approved DPC on tanking primer, DPC to lap onto face of concrete wall to manufacturers specification
Refer to Structural Engineer's drawings and specifications for all information on structural frame/ elements. Refer to Mechanical Engineer's drawings and specifications for all information on mechanical and electrical items.
Waterproofing Detail (basement) 03 1310(AS)01-01
LIFT SHAFT FFL Screed
FFL Raised timber
SSL
SSL
Specific Notes
Lift pit depth subject to Durkan's confirmation of lift specification
1240 (TBC)
LIFT PIT
AS BUILT Legend
B
ion
m
A Un
ad
D
Ro
B1 / LIVE WORK BASEMENT
ha
B1 / LIVE WORK BASEMENT
C
Ro
ad
Cl ap
COMMUNAL AREA BASEMENT
N
Key
Uretek lightweight pumped void filler to SE details
Waterbar at kicker, details refer to SE dwgs
Note: Durkan to confirm buildability and client to confirm use of space.
Screed with floor finish to communal area
BLOCK B = nom.740mm
FFL Screed BLOCK C = nom.560mm
SSL BLOCK D = nom.580mm B A -
Unimortar fillet
PW 18.03.16 TSo 02.09.13 TSo 14.06.13
Issued, As Built Issue for constrcution First issue
Rev
Comment
By
Date
Vandex BB75 waterproofing slurry applied to void area to manufacturer details
stephen davy architects peter smith
FFL Screed
LIFT PIT
SSL
1240 (TBC)
Lift pit depth subject to Durkan's confirmation of lift specification
Fanshaw House, Fanshaw Street, London N1 6HX Tel: 020 7739 2020 Fax: 020 7739 2021 E-mail:
[email protected] Website: www.davysmitharchitects.co.uk
Unimortar fillet Vandex BB75E waterproofing slurry applied to retaining wall within lift shaft and pit area, Vandex construction joint tape to joints to manufacturer details
Client
4 Elstree Gate Elstree Way Borehamwood Hertfordshire WD6 1JD Project
Union Road Union Road / Clapham Road Clapham SW4 Drawing Title
Job No.
Drawn By
Scale
1310
TSo
1:10 @ A1
Date
Checked By
June 2013
GD
Drawing No.
1310(AS)01-02
Revision
B