Locking Control Door Accessory Kit


[PDF]Locking Control Door Accessory Kit - Rackcdn.com9459a8a7c04856c345d2-4f8300507cf0a318260a6776e1a92a67.r99.cf1.rackcdn.co...

1 downloads 135 Views 64KB Size

Locking Control Door Accessory Kit For Use with Packaged Terminal Air Conditioner or Heat Pump

Installation Instructions INTRODUCTION

INSTALLATION

These instructions cover the installation of the Locking Control Door Accessory Kit. See Fig. 1.

Remove Front Panel — Remove front panel from the unit by grasping the panel firmly near the bottom of both sides, then pulling panel forward and upward to release magnetic latches and partition hooks. See Fig. 2.

PACKAGE CONTENTS ITEM Locking Control Door Lock Strike Plate* Keys (Identical) Strike Plate Attachment Screw*

QUANTITY 1 1 2 1

*Not required on some units.

Remove Existing Control Door 1. Turn over front panel. 2. From backside of front panel, remove 2 control door hinge pins and set aside. See Fig. 3. 3. Remove and discard door.

Attach Locking Control Door

LOCKING CONTROL DOOR

1. Position new locking control door on front side of front panel where previous door was located. 2. Line up attachment hinge holes in locking control door with holes in front panel. 3. While holding door in place, re-attach 2 control door hinge pins into hinge pin holes on backside of front panel. See Fig. 3.

CONTROL DOOR HINGE PINS

KEYS

STRIKE PLATE ATTACHMENT SCREW (IF REQUIRED)

LOCK STRIKE PLATE (IF REQUIRED)

Fig. 1 — Locking Control Door Assembly CONTROL PANEL DOOR

INSIDE VIEW FRONT PANEL

LOCK SLOT

LOCK STRIKE PLATE (IF REQUIRED)

Fig. 3 — Removing Hinge Pins From Back of Front Panel

Fig. 2 — Removing Front Panel Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. PC 132 Catalog No. 535-20048 Printed in U.S.A. Form 52C,P-23SI Pg 1 9-02 Replaces: 52C,P-13SI Book 1 4 Tab 9a 11a

Attach Strike Plate (If Required)

Final Assembly and Operation

1. If lock slot in plastic panel is 1-in. long, then the strike plate is not needed. If lock slot is approximately 23/8-in. long, complete the steps below to attach the required strike plate. 2. From inside of front panel, line up strike plate with lock slot in front panel. See Fig. 3. 3. From top front of front panel, line up strike plate screw hole to left most position of slot. 4. Install attachment screw. Do not over tighten. See Fig. 4.

1. 2. 3. 4.

Reinstall front panel. Close and lock door. See Fig. 5. Be sure keys can easily be inserted and removed. Verify door is secure.

IMPORTANT: For best installation and proper lock operation, be sure strike plate attachment screw is installed in the left most position of the lock slot. HI T HEA

FAN

LER COO MER WAR

Fig. 5 — Completed Assembly

ATTACHMENT SCREW

STRIKE PLATE

LOCK SLOT

Fig. 4 — Location of Attachment Screw

Copyright 2002 CAC/BDP Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. PC 132 Catalog No. 535-20048 Printed in U.S.A. Form 52C,P-23SI Pg 2 9-02 Replaces: 52C,P-13SI Book 1 4 Tab 9a 11a