Logic Control in Tesira


[PDF]Logic Control in Tesira - Rackcdn.comc353616.r16.cf1.rackcdn.com/Biamp_Tech_Note_Logic_Control_in_Tesira.pdfCachedSimilarVoIP Dialer. 34 logic in...

97 downloads 209 Views 251KB Size

Logic Control in Tesira

Device

Logic I/O

1 logic input per audio channel, up to 16 channels per block (56 ganged)

Operation

Logic input 1 causes audio channel to mute. Logic input 0 causes audio channel to un-mute.

Mute Control

1 logic input for level up (+) on each audio channel. 1 logic input for level down (-) on each audio channel. Level Inc/Dec

Up to 32 audio channels per block (64 ganged)

1 logic input per preset, up to 10 presets per block

Logic 1 input to (+) causes level to ramp up. Logic 1 input to (-) causes level to ramp down. Optional: Disable ramping Transition from logic 0 to 1 on (+) causes audio to increment up. Transition from logic 0 to 1 on (-) causes audio to increment down.

Transition from logic 0 to logic 1 triggers preset to recall

Remote Preset

19 logic inputs and 1 logic output

Transition from logic 0 to logic 1 on input 1 to 16 causes the associated speed dial number to be dialed. Transition from logic 0 to logic 1 on Rdl input causes the last number to be redialed.

TI Dialer

34 logic inputs (17 for each line) VoIP Dialer

BIAMP SYSTEMS TECHNICAL SUPPORT GROUP

Transition from logic 0 to logic 1 on input 1-x to 16x causes the associated speed dial number in the corresponding line to be dialed. Transition from logic 0 to logic 1 on Rdl-x input causes the last number to be redialed in the corresponding line.

www.biamp.com



Page 1 of 9

1 logic output per input channel, up to 256 channels per block

Logic output normally Logic 0 Switches to Logic 1 as long as corresponding input channel is gated on. Optional: Behavior of logic output may be inverted in control dialog.

Gating Auto Mixer

1 logic input per partition plus 5 source selection inputs (4 sources + Off) per room, up to 32 rooms (58 partitions) per block

Room Combiner

1 logic output per partition plus 5 source selection outputs (4 sources + Off) per room, up to 32 rooms (58 partitions) per block

Logic 0 on partition input causes partition to remain open. Logic 1 on partition input causes partition to remain closed Transition from logic 0 to 1 on source inputs selects the corresponding audio source (or Off) for the corresponding room Logic 0 on partition output indicates partition is open Logic 1 on partition output indicates partition is closed Logic 1 on any source selection output indicates that source (or Off) is selected for that room

1 Logic input per channel, up to 32 channels 1 Logic output per channel, up to 32 channels

Transition from logic 0 to 1 on logic inputs selects the corresponding audio source Logic outputs normally logic 0. Logic 1 on logic output indicates corresponding audio source is selected

Source Selection 1 on logic input causes program audio to duck and logic output to be 1. 0 causes program to un-duck. 1 logic input and 1 logic output Ducker

BIAMP SYSTEMS TECHNICAL SUPPORT GROUP

Audio signal exceeding threshold on sense input causes logic output to be 1. Audio signal below threshold causes logic output to be 0. Optional: Behavior of logic control may be inverted in control dialog.

www.biamp.com



Page 2 of 9

A logic 1 indicates the AGC is applying or reducing gain 1 logic output In Speech Mode, a logic 1 indicates Speech is being detected

AGC

Logic outputs 1 thru D pulse high for 250msec when the corresponding DTMF tone is detected. 17 logic outputs DTMF Decode

BIAMP SYSTEMS TECHNICAL SUPPORT GROUP

Logic output Any pulses high for 250msec when any DTMF tone is detected.

www.biamp.com



Page 3 of 9

Logic 1 on HS input picks up the line or “takes off hook”. Logic 0 causes the line to hang up or “Put back on hook” Transition from logic 0 to logic 1 on HF input causes a hook flash. Logic 1 on RI = line is ringing Logic 0 on RS = line is not ringing Logic 1 on DIP = Dialing in progress Logic 0 on DIP = Not dialing Logic 1 on HSS = Off hook Logic 0 on HSS = On hook

2 logic inputs and 10 logic outputs

Logic 1 on DTD = Dial tone detected Logic 0 on DTD = No dial tone Logic 1 on BTD = Busy tone detected Logic 0 on BTD = Busy tone not detected

TI Control/Status Logic 1 on RTD = Ring tone detected Logic 0 on RTD = No ring tone detected Logic 1 on LR = Line ready Logic 0 on LR = Line not ready Logic 1 on LIU = Line in use Logic 0 on LIU = Line not in use Logic 1 on LI = Line intrusion Logic 0 on LI = No line intrusion Logic 1 on LF = Line fault detected Logic 0 on LF = No line faults

BIAMP SYSTEMS TECHNICAL SUPPORT GROUP

www.biamp.com



Page 4 of 9

Transition from 0 to 1 on ANS x.y answers the call on appearance x line y Transition from 0 to 1 on END x.y ends the call on appearance x line y

VoIP Control/Status

24 logic inputs (two per appearance per line) and 26 logic outputs (two per appearance per line plus 2 per line)

Logic 1 on RI x.y indicates appearance x on line y is ringing Logic 1 on LIU x.y indicates appearance x on line y is in use Logic 1 on LR1 (LR2) = Line 1 (2) in line ready mode Logic 0 on LR1 (LR2) = Line 1 (2) in not ready mode

Network Command String

Serial Command String

1 logic input per command string, up to 32 per block

Transition from logic 0 to 1 triggers command string to output network port.

1 logic input per command string, up to 32 per block

Transition from logic 0 to 1 triggers command string to output serial port.

Open on logic input = Logic 1 Closure on logic input= Logic 0 Up to 16 channels Logic Input

BIAMP SYSTEMS TECHNICAL SUPPORT GROUP

Optional: Behavior of logic control may be inverted in control dialog.

www.biamp.com



Page 5 of 9

In Logic mode Logic 1 on logic output = open Logic 0 on logic input =closure Up to 16 channels

In LED Driver mode Logic 1 on logic output = Up to 24V/500mA Logic 0 on logic input = Short to ground Optional: Behavior of logic control may be inverted in control dialog.

Logic Output/LED Driver

1 logic input and 1 logic output per delay, up to 32 per block Logic Delay

1 on logic input must be present for specified ON time before logic output changes to 1. 0 on logic input must be preset for specified OFF time before logic output changes to 0.

1 at either or both logic inputs causes a 1 at logic output. Otherwise, logic output is 0. Truth table: Input 1 Input 2 2-32 logic inputs and 1 logic output OR Gate

Output

0

0

0

0

1

1

1

0

1

1

1

1

1 at both inputs causes a 1 at logic output. Otherwise, logic output is 0. Truth table: Input 1 Input 2 2-32 logic inputs and 1 logic output AND Gate

BIAMP SYSTEMS TECHNICAL SUPPORT GROUP

Output

0

0

0

0

1

0

1

0

0

1

1

1

www.biamp.com



Page 6 of 9

1 at logic input causes a 0 at logic output. 0 at logic input causes a 1 at logic output. 1 logic input and 1 logic output per gate, up to 32 per block NOT Gate

Truth table: Input Output 1

0

0

1

0 at both logic inputs causes a 1 at logic output. Otherwise, logic output is 0. (Logically the same as an OR gate followed by a NOT gate.)

2-32 logic inputs and 1 logic output NOR Gate

Truth table: Input 1 Input 2

Output

0

0

1

0

1

0

1

0

0

1

1

0

1 at both logic inputs causes a 0 at logic output. Otherwise, logic output is 1. (Logically the same as an AND gate followed by a NOT gate.)

2-32 logic inputs and 1 logic output NAND Gate

BIAMP SYSTEMS TECHNICAL SUPPORT GROUP

Truth table: Input 1 Input 2

Output

0

0

1

0

1

1

1

0

1

1

1

0

www.biamp.com



Page 7 of 9

1 at either but not both logic inputs causes a 1 at logic output. Otherwise, logic output is 0. Truth table: Input 1 Input 2 2-32 logic inputs and 1 logic output XOR Gate

1 logic input and 1 logic output per gate, up to 32 per block

Output

0

0

0

0

1

1

1

0

1

1

1

0

0 to 1 transition at logic input causes logic output to toggle from its present state to the opposite state.

Flip Flop Gate

1 logic input per meter, up to 32 per block

Logic 1 on input node turns corresponding indicator on Logic 0 on input node turns corresponding indicator off

Logic Meter

1 logic output per state, up to 32 per block

Setting a State On causes the corresponding logic output to be 1. Setting the State Off causes the corresponding logic output to be 0

2-32 logic inputs and 1 logic output

Transition from logic 0 to logic 1 on any of the inputs generates a 150ms logic pulse on the output

1 logic input per meter, up to 32 per block

Audio signal exceeding threshold on sense input causes logic output to be 1. Audio signal below threshold causes logic output to be 0.

Logic State

Fan-In OP Pulse

Signal Present Meter

BIAMP SYSTEMS TECHNICAL SUPPORT GROUP

www.biamp.com



Page 8 of 9