GENERAL NOTES
HEDGE PLANTING SCHEDULE Code
CMO
Name
Crataegus Monogyna
Height (cms)
60-80
Root Cont. Girth (litres) (cms)
BR
-
-
Clear Stem
-
Age
Habit/Form
1+1or1/1 Transplant-seed raised
Breaks
-
Code Total Area/ Spacing 275m2
0.8m
Total
140 140
AMENITY PLANTING SCHEDULE Code
LEFT VISABILITY SPLAY 2.0m x 45.0m
Name
Height (cms)
Root Cont. Girth (litres) (cms)
Clear Stem
Age
Habit/Form
Breaks Code Total Area/ Spacing
TCGR
Tilia Cordata 'Greenspire'
min450
RB
-
16-18
min200 3x
Standard (Extra Heavy)
-
Spec
10
SAU
Sorbus Aucuparia
60-80
BR
-
-
-
1+1or1/1 Transplant-seed raised
-
1.2m
10
FSY
Fagus Sylvatica
250-300 RB
-
8-10
-
2x
5
2.4m
10
BPE
Betula Pendula
60-80
-
-
-
1+1or1/1 Transplant-seed raised
-
1.2m
10
BR
Feathered
Total
40
GENERAL NOTES: All workmanship to be in accordance with BS4428 1998. All trees and large shrubs, closely adjacent to service strips to have "Reroot 2000" root barrier or other equal and approved, to protect services. Woodland areas to have scrub cut to ground level prior to planting. All Heights given in (cm's), RB - Rootballed, BR - Bare Root, C - Container Grown. Container sizes given in Litres. All in accordance with the National Plant Specification, as published by the Horticultural Trades Association. NOTE WHERE NEW TREES ARE TO BE PLANTED, THEY SHALL BE AS PER PLANTING SCHEDULE TOP RIGHT.
SITE / ACCESS NOTES VISIBILITY SPLAYS
1. THE AREA WITHIN THE VISIBILITY SPLAYS SHALL BE CLEARED TO PROVIDE A LEVEL SURFACE NO HIGHER THAN 250 MM ABOVE THE LEVEL OF THE ADJOINING CARRIAGEWAY AND SHALL BE RETAINED AND KEPT CLEAR THEREAFTER. ANY POLE OR COLUMN MATERIALLY AFFECTING VISIBILITY MUST ALSO BE REMOVED. NO WORK SHALL COMMENCE ON SITE UNTIL THE VISIBILITY SPLAYS HAVE BEEN PROVIDED 2. THE LINE OF ANY NEW FENCE OR WALL MUST BE POSITIONED BEHIND THE VISIBILITY SPLAYS. IT IS RECOMMENDED THAT ANY NEW TREES OR SHRUBS BE PLANTED AT LEAST 3.0 M BACK FROM THE VISIBILITY SPLAYS TO ALLOW FOR FUTURE GROWTH AND SOME SPECIES WILL REQUIRE ADDITIONAL SET BACK. ALL EXISTING PLANTING MUST BE KEPT TRIMMED BEHIND VISIBILITY SPLAYS. DRAINAGE
3. DRAINAGE SHALL BE PROVIDED WHERE NECESSARY TO PREVENT WATER FROM THE ACCESS FLOWING ONTO THE PUBLIC ROAD. SIMILARLY THE EXISTING ROAD DRAINAGE MUST BE ACCOMMODATED WHERE APPROPRIATE AND MEASURES MUST BE TAKEN TO PREVENT ROAD SURFACE WATER FROM FLOWING ONTO THE ACCESS. 4. ANY OPEN DRAINS IN THE ROAD VERGE SHALL BE PIPED TO THE SATISFACTION OF DOE ROADS SERVICE. OPEN DRAINS BEHIND THE FENCE/HEDGELINE SHALL BE PIPED TO THE SATISFACTION OF THE DEPARTMENT OF AGRICULTURE WATERCOURSE MANAGEMENT DIV. GRADIENT
5. WHERE THE VEHICULAR ACCESS CROSSES A FOOTWAY, THE ACCESS GRADIENT SHALL BE BETWEEN 4% (1:25) MAXIMUM AND 2.5% (1:40) MINIMUM AND SHALL BE FORMED SO THAT THERE IS NO ABRUPT CHANGE OF SLOPE ALONG THE FOOTWAY.
NOTE HATCHED AREAS OF HEDGEROW INDICATING NEW HAWTHORN BOUNDARY BEHIND SIGHT VISABILITY SPLAYS.
GATES SECURITY BARRIERS
6. ENTRANCE GATES, WHERE ERECTED SHOULD BE SITED AT LEAST 5 METRES FROM THE EDGE OF THE CARRIAGEWAY. WHERE THIS IS NOT POSSIBLE THEY SHALL BE SITED SO THAT WHEN OPEN THEY DO NOT PROJECT OVER THE FOOTWAY, VERGE OR CARRIAGEWAY. 7. IN THE CASE OF INDUSTRIAL PREMISES OF OTHER MAJOR ACCESSES, GATES OR SECURITY BARRIERS SHALL BE LOCATED AT A DISTANCE FROM THE EDGE OF THE CARRIAGEWAY THAT WILL ALLOW THE LARGEST VEHICLE LIKELY TO USE THE ACCESS TO STOP CLEAR OF THE CARRIAGEWAY WHEN THE GATES OR BARRIERS ARE CLOSED.
PARKING
PARKING/TURNING
8. THE REQUIRED VEHICLE PARKING AND TURNING AREA TO BE PROVIDED WITHIN THE CURTAILAGE OF THE SITE.
SITE LEVELS
RIGHT VISABILITY SPLAY 2.0m x 45.0m
SOAKAWAY
EXISTING GROUND LEVEL (G.L.) AT DWELLING - 99.700 PROPOSED REDUCED G.L. AT DWELLING - 99.700 (NO CHANGE)
PARKING
FINISHED FLOOR LEVEL (F.F.L.) AT DWELLING - 100.000
BIO DISC TREATMENT PLANT
NOTE PROPOSED NEW DRIVEWAY AND PATHWAYS AROUND HOUSE TO BE FINISHED WITH GRAVEL
SEPTIC TANK / SOAKAWAYS
9. POSITION OF THE SEPTIC TANK TO BE SHOWN. DRAINAGE MUST NOT BE DISCHARGED DIRECTLY TOWARDS THE PUBLIC ROAD OR INTO ANY DRAIN LEADING TO THE PUBLIC ROAD. SOAKAWAY LENGTH DETERMINED BY ENVIRONMENT & HERITAGE SERVICE. APPLICATION FOR DISCHARGE CONSCENT SHALL BE THE RESPONSIBILITY OF THE CLIENT.
NOTE DASHED LINE INDICATING POSITION OF PREVIOUS APPROVED DWELLING PLANNING REF: L / 2006 / 2438
NOTE NEW SOUTHERN BOUNDARY TO PROPOSED SITE SHALL BE A TIMBER POST AND WIRE STOCK PROOF FENCE WITH A NATIVE SPECIES HEDGEROW PLANTED ON THE INSIDE.
Client:
Mr Harold Hassard
Project:
Proposed Change Of Housetype For Already Approved Dwelling
Address:
Grogey, Fivemiletown County Fermanagh Irish Grid Ref: 243560 / 342350
PROPOSED SITE LAYOUT
Title:
Proposed Site Layout
Date:
Feb. 2009
Scale:
1:500
Job Number:
scale 1:500
2
R
DeSigN
RSC
Drawn By: Sheet:
HH Grogey
BC02
'The Studio' 40 Inishmore Killyleagh, Co.Down BT30 9TP Tel: 02844 821740 Mobile: 07788 884787 e-mail:
[email protected]