Round washed pebbles, graded 20-40mm to provide 500mm wide vegetation barrier around perimeter and all upstands & penetrations.
General Notes C
1:80 fall
50mm thk (min.) paving slabs on adjustable pads Adjustable paving support
Loose laid separation layer as part of waterproofing system, installed in accordance with manufacturer's requirements. 220
220mm thick BBA approved XPS insulation to meet required U-value.
180mm thick BBA approved IKO Enertherm insulation to meet required U-value.
Reinforced concrete floor slab, 2400 kg/m3 min., to Structural Engineer's specification and requirement. Laid to falls (1 in 80)
nom. 150
RESIDENTIAL UNIT
R1 01
Fire rating: Acoustic rating: Thermal rating:
1310 (AS) 04/02
All elements of work and materials are to comply with Building Regulations and British Standards, good industry practice and the recommendations of material and component manufacturers. All drawings are indicative only. The sub-contractor is to submit shop drawings to the contract administrator of all the relevant components and elements for comment prior to fabrication. All products are to be suitable for their purpose. The Contractor is to install all products where noted in accordance with manufacturers' recommendations/specifications and inform the Architect of any discrepancies or changes in the specification before proceeding with the work. This drawing is to be read in conjunction with all other relevant documentation including that produced by other consultants, subcontractors and suppliers. Refer to Structural Engineer's drawings and specifications for all information on structural frame/ elements.
Specific Notes
R#
as type R1
Rigid insulation to soffit to achieve required U-Value, thickness tbc.
SW#
15mm Gyproc Wallboard with 3mm plaster skim and paint finish to be installed in accordance with manufacturer's recommendations. Plasterboards to be fixed to suspended ceiling system.
RESIDENTIAL UNIT
To achieve min. 60mins as Building Regulations Approved Document B. N/A To achieve minimum U-Value of 0.13W/m2K or better. Calculated U-Value: 0.13W/m2K
MAIN ROOF
All dimensions are given in millimetres, and internal dimensions are taken to face of structure. Do not scale from the drawing. All dimensions and conditions to be checked and confirmed on site by the Contractor. The Contractor should inform the Architect of any discrepancies before proceeding with the work.
F#
Reinforced concrete floor slab, 2400 kg/m3 min., to Structural Engineer's specification and requirement. To be primed with PermaTEC Primer to manufacturer's requirements.
Gyproc suspended ceiling system, Gyproc CasoLine MF system or similar approved.
Copyright Stephen Davy Peter Smith Architects 2012
Refer to Mechanical Engineer's drawings and specifications for all information on mechanical and electrical items.
200 / 225
IKO Systems PR vapour control layer
BBA approved hot melt zero-falls waterproofing system such as Iko Permatec or equal approved. Waterproofing layers comprising 2 coats of PermaTEC ECOWRAP incorporating PermaFLASH-R reinforcement, finish with PermaGUARD-F protection layer. All to manufacturers recommendations
SSL
10-20
SSL
200
10-20
180
IKO Goldseal T-O Slate bituminous torch-on capping sheet with compatible IKO Systems Underlayer. All to manufacturers recommendations and in accordance with BBA requirements.
50
OUTSIDE
20-30
OUTSIDE
R2 02
Fire rating: Acoustic rating: Thermal rating:
1310 (AS) 04/02
To achieve min. 60mins as Building Regulations Approved Document B. N/A To achieve minimum U-Value of 0.13W/m2K or better. Calculated U-Value: 0.13W/m2K
TERRACES
AS BUILT Legend
Key
C B
Issued, As Built R1 changed to IKO Goldseal T-O Bituminous Waterproofing System
A
Terrace insulation thickness amended, issued for GD 19.08.13 construction First Issue KK 23.07.13
Rev
PW 18.03.16 WG 13.05.14
Comment
By
Date
Stephen Davy Peter Smith Architects Fanshaw House, Fanshaw Street, London N1 6HX Tel: 020 7739 2020 Fax: 020 7739 2021 E-mail:
[email protected] Website: www.davysmitharchitects.co.uk
Client
4 Elstree Gate Elstree Way Borehamwood Hertfordshire WD6 1JD Project Title
Union Road / Clapham Road London SW4 Drawing Title
Roof Types
Job No.
Drawn By
Scale
1310
KK
1:5 @ A1
Date
Checked By
July 2013 Drawing No.
1310 (AS) 04/02
Revision
C