Self-Service Open Multi-Deck End-Cap Island ... - Hillphoenix


[PDF]Self-Service Open Multi-Deck End-Cap Island...

3 downloads 102 Views 254KB Size

Self-Service Open Multi-Deck End-Cap Island Merchandiser & End Cap HVI 3’ DEEP & 62” TALL SELF-CONTAINED - 305 & 305-EC System Requirements Model

Volts

HVI-3

Total Amps

Phase

Minimum Circuit Ampacity

Maximum Overcurrent Protection

305

Electrical Data Fans per Case

Model HVI-3

305

High Efficiency Fans

Anti-Condensate Fans

Drain Pumps

120 Volts

120 Volts

120 Volts

Amps

4

Watts

1.2

Amps

138

---

Auxiliary Fans

Evaporator Pan Heaters

120 Volts

Watts

Amps

Watts

Volts

Amps

Watts

Amps

Watts

---

---

---

208

7.2

1500

---

---

1

Lighting Data

Model HVI-3

Lights per Row

Light Length (ft)

Amps

1

10

---

305

Clearvoyant LED Lighting (Per Light Row)

Fluorescent Lighting (Per Light Row)

Standard Power (Cornice or Shelf)

High Power (Cornice)

120 Volts

120 Volts

120 Volts

Watts

Maximum Allowable Rows

Amps

---

---

---

Watts

Maximum Allowable Rows

Amps

Watts

Maximum Allowable Rows

---

---

0.35

42.2

2

Guidelines & Control Settings 2

Model

24hr Energy Usage (kWh/ft)

Suction Temperature @ Case Outlet (oF)

Superheat Set Point @ Bulb (oF)

Discharge Air (oF)

Discharge Air Velocity (FPM)

HVI-3

---

55.3

10

32

150

Condensing Unit Data 3

Model HVI-305-EC

305

Condenser Fans

4

Volts

Phase

HP

RLA (amps)

LRA (amps)

Refrig.

Amps

Watts

Lbs. of Refrig.

208

1

1.5

7.5

40

404a

0.94

196

5.8-0.6

Defrost Controls Electric Defrost

Timed-Off Defrost

Hot Gas Defrost

Model

Defrosts per Day

Run-Off Time (min)

Fail-Safe (min)

Termination Temp (oF)

Fail-Safe (min)

Termination Temp (oF)

Fail-Safe (min)

Termination Temp (oF)

HVI-305-EC

6

---

---

---

30

42

---

---

1

NOTE: “- - -” indicates data not applicable.

2

Average discharge air velocity at peak of defrost.

3

RLA - Running Load Amps

4

LRA - Locked Rotor Amps

Engineered for stores with ambient conditions not to exceed 75o and 55% relative humidity. Due to engineering improvements specifications may change without notice. All measurements are taken per ASHRAE - 72 - 2005 specifications. Numbers are based on standard case sizes. Consult engineering.

04/16

HVI-3-305 (3’ Deep & 62” Tall Self-Contained)

8 in [20.3 cm]

61 7/8 in [157.1 cm]

10 in [25.4 cm]

10 in [25.4 cm]

12 in [30.4 cm]

12 in [30.4 cm]

7 7/16 in [18.8 cm]

7 7/16 in [18.8 cm]

Bakery / Beverage / Dairy / Deli / Produce

28 11/16 in [72.9 cm]

8 in [20.3 cm]

SELF-SERVICE MULTI-DECK

26 1/2 in [67.4 cm]

LOAD LIMIT LINE

11 in [27.9 cm]

28 9/16 in [72.5 cm] 16 15/16 in [43.1 cm]

COMPRESSOR COMPARTMENT

C L 29 3/4 in [75.6 cm] 36 in [91.4 cm]

36 in [91.5 cm] TOEKICK

3 1/8 in [8.0 cm] 36 in [91.4 cm]

32 7/8 in [83.5 cm]

C L

C L 60 in [152.4 cm] 04/16

TOEKICK

HVI-3-305-EC (3’ Deep & 62” Tall End Cap Self-Contained) 26 1/2 in [67.4 cm]

LOAD LIMIT LINE

8 in [20.3 cm]

28 11/16 in [72.9 cm]

61 7/8 in [157.1 cm]

7 7/16 in [18.8 cm]

8 in [20.3 cm]

10 in [25.4 cm]

10 in [25.4 cm]

12 in [30.4 cm]

12 in [30.4 cm]

7 7/16 in [18.8 cm]

11 in [27.9 cm]

28 9/16 in [72.5 cm] 16 15/16 in [43.1 cm]

COMPRESSOR COMPARTMENT

C L 29 3/4 in [75.6 cm] 36 in [91.4 cm]

50 in [127.1 cm] TOEKICK

3 1/8 in [8.0 cm]

C L

36 in [91.4 cm]

32 7/8 in [83.5 cm]

TOEKICK

C L 60 in [152.4 cm] 04/16